Defining Alerts

To define how and to whom Antivirus sends alerts when an virus is detected, select 8. Alerting from the Antivirus & AntiRansomware (ATP) Configuration screen (STRAV> 81). The Alerting screen appears:

                                   ​ Alerting​                                    
                                                                                
 Type options, press Enter.​                                                     
                                                                                
 Inform QSYSOPR . . . . . . . . . .​  Y          ​ Y=Yes, N=No​                    
 Inform SIEM  . . . . . . . . . . .​  Y          ​ Y=Yes, N=No​                    
                                                                                
 Send Email to (mail1,mail2..). . .​  VV , orenc                                 
                                    ​
                                            
 Batch jobs also send alerts  . . .​  Y          ​ Y=Yes, N=No​                    
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
 F3=Exit​  ​ F12=Previous​                                                         
                                                                             ​  ​ 

The body of the screen contains these fields:

Inform QSYSOPR

Whether to send a message to QSYSOPR when a virus is detected. Possible values are:

  • Y: Send messages to QSYSOPR
  • N: Do not send messages to QSYSOPR.

Inform SIEM

Whether to send alerts to SIEM systems when a virus is detected. You can set up to three SIEM systems for alerts via the iSecurity/Base System Configuration screen (STRAUD> 81) as shown in the Audit manual.

Possible values are

  • Y: Send messages to SIEM
  • N: Do not send messages to SIEM.

Send Email to

Send email to these addresses when a virus is detected.

Batch jobs also send alerts

Whether to send alerts when batch jobs, as well as real -time scans, detect viruses.